返回顶部
首页 > 资讯 > 错误编码 >ORA-19734: wrong creation SCN – control file expects converted plugged-in datafile ORACLE 报错 故
  • 714
分享到

ORA-19734: wrong creation SCN – control file expects converted plugged-in datafile ORACLE 报错 故

报错故障creation 2023-11-05 01:11:51 714人浏览 安东尼
摘要

文档解释 ORA-19734: wrong creation SCN – control file expects converted plugged-in datafile Cause: When a tablespace i

文档解释

ORA-19734: wrong creation SCN – control file expects converted plugged-in datafile

Cause: When a tablespace is plugged into a database, the tablespace is initially read-only. oracle converts the header of the plugged-in datafiles (assign them a new creation SCN) when the tablespace is first made read-write. This error occurs when the creation SCN in the file header is different from the creation SCN in the control file, possibly because this is the initial version of plugged-in datafile.

Action: Either restore the converted datafile or continue recovering the datafile.

ORA-19734是由于控制文件期望插入的数据文件被转换而导致的错误。

官方解释

Oracle报ORA-19734 表明控制文件期望拔插的数据文件已被转换,从而无法推断备份的SCN号。

常见案例

如果在一个数据库中错误地在任何时间备份相同的数据文件,就可能会发生此错误。此外,当在水平分区中更改分区上的分区提供程序后,也可能会发生此错误。

一般处理方法及步骤

1.确定问题的现象,明确当前的工作环境。

2.检查数据库alert日志操作系统日志的内容,查看是否存在相关的故障症状。

3.检查相关的trace文件,确定问题的报错信息及错误参数。

4.查询官方文档,找到相关的ORA错误的具体定义,确定错误的原因及解决方案。

5.采取解决问题的措施,解决问题并对系统作出稳定改善。

--结束END--